Sim, conforme o manual do PIC16F877A, é necessário que a impedância de saída das fontes de sinal sejam inferiores a 2,5 Kohms para não haver erro de leitura.
Creio que interpretamos a recomendação de maneiras diversas ... O fragmento relevante da DS:
[info]
11.1 A/D Acquisition RequirementsFor the A/D converter to meet its specified accuracy,
the charge holding capacitor (CHOLD) must be allowed to fully charge to the input channel voltage level. The analog input model is shown in Figure 11-2. The source impedance (RS) and the internal sampling switch impedance (RSS) directly affect the time required to charge the capacitor CHOLD. The sampling switch (RSS) impedance varies over the device voltage (VDD); see Figure 11-2. The maximum recommended impedance for analog sources is 2.5 kΩ. As the impedance is decreased, the acquisition time may be decreased. After the analog input channel is selected (changed), this acquisition must be done before the conversion can be started.[/info]
Se bem entendo, a questão aqui é garantir a carga de CHOLD até a tensão amostrada, o que pode ser obtido pela manipulação de
Tacq ... tô enganado ?
Não analisei para o valor discutido [ 10K ] mas creio que este é um recurso viável, se não neste caso específico, em outros ...